Furnace Condensate Pump Not Working?

What the small pump beside your high-efficiency furnace does, the signs it has stopped, the safe checks you can make and when a technician should take over.

Furnace condensate pump not working beside a high-efficiency furnace with a small puddle of water on the basement floor
24/7 Service
TSSA-Registered
Since 1990
NATE-Certified
$79 Service Call*
MA Matthew Arbab, Owner of Aire One Heating & Cooling
By Matthew Arbab
Owner, Aire One Heating & Cooling · Updated November 26, 2026

The short answer: A furnace condensate pump not working usually shows up as water beside the furnace, a pump that hums nonstop or never runs, or a furnace that shuts itself off. Common causes are lost power, a stuck float, a clogged reservoir or a blocked or frozen drain line. Look for loose plugs and kinked tubing, stay away from water near outlets, and let a technician clean, test or replace the pump.

Most homeowners never notice the small pump beside their furnace until something goes wrong. Then the signs are hard to miss: a puddle, a damp basement carpet or a house getting colder by the hour. A furnace condensate pump not working is a common winter call in Ontario homes with high-efficiency furnaces, and once the cause is found, the repair is usually straightforward.

This guide covers what the pump does, the symptoms of a failure, what you can safely check and what a technician does next. If the heat is off, you can book a service visit online or call 310-HEAT any time, day or night.

Furnace condensate pump not working and water on the floor? Start here.

  • Keep away from water near electricity. If water has reached an outlet, power bar or cord, touch nothing, keep everyone back and call a professional.
  • Unplug before you touch. Only when the floor and outlet area are completely dry should you unplug the pump, with dry hands, before looking closer.
  • Mop up small puddles. Health Canada notes that mould can begin to grow within 48 hours, so dry the area quickly.
  • Smell rotten eggs? Leave the home and call Enbridge Gas at 1-866-763-5427 or 911 from outside.

What a Condensate Pump Does on a High-Efficiency Furnace

High-efficiency furnaces squeeze extra heat out of their exhaust. Natural Resources Canada explains that in the condensing section, combustion gases are cooled until the water vapour condenses, and that this condensate is piped to a floor drain or a condensate pump. When there is no drain low enough nearby, a pump moves the water instead.

Here is the path the water usually takes:

1. Furnace
Water forms as exhaust cools.
2. Trap and hose
A trap and hose lead to the pump.
3. Reservoir
Water collects in a small tank.
4. Float
A rising float starts the motor.
5. Discharge line
Tubing carries water to a drain.

Many pumps also have an overflow safety switch. When it is connected to the furnace or air conditioner, it turns the system off if water climbs too high. In summer, the cooling coil of a central air conditioner often drains into the same pump.

Signs of a Furnace Condensate Pump Not Working

A furnace condensate pump not working rarely stays hidden for long. Match what you notice to the likely cause:

Water around the pump or furnace

Overflowing tank, loose hose or a crack.

The pump never runs

No power, a float stuck down or a failed motor.

The pump runs and runs

A float stuck up, a blocked line or water flowing back.

Loud gurgling, rattling or humming

A short gurgle is normal. Grinding or a steady hum points to a worn motor.

Furnace shuts off or will not start

A safety switch stopped it because water is backing up.

Musty smell or slime in the tank

Sludge left over from air conditioning season.

If the status light is flashing, note the pattern before you call. Our guide to a furnace blinking light explains those codes.

Common Causes of a Furnace Condensate Pump Not Working

Most failures come down to one of five things:

  1. No power. The plug was bumped loose, a switch controlling the outlet was turned off, or a breaker tripped. Water near a cord can trip a breaker too, so read our guide on a furnace tripping the breaker before anyone touches the panel.
  2. A stuck float. Sludge can hold the float up or down, so the motor never starts or never stops.
  3. A clogged reservoir or inlet. Over time, condensate leaves a film and debris that slow the pump and can block the inlet.
  4. A blocked, kinked or frozen discharge line. The pump runs, but water has nowhere to go.
  5. A worn motor, check valve or tank. A failed check valve lets water run back into the tank, and older tanks can crack.

Sometimes the pump is fine and the furnace itself is the source of the water. Our article on why a gas furnace leaks water covers those causes, and a clogged internal drain is one of the common combustion problems with high-efficiency furnaces.

Six Safe Checks for a Furnace Condensate Pump Not Working

These checks involve looking, not repairing. None need tools, opening the furnace or touching wiring.

☐ 1. Look at the floor first. If water is near an outlet or cord, stop here and call.

☐ 2. Look at the plug. If it has simply come loose and everything around it is dry, push it back in with dry hands.

☐ 3. Check that the outlet is on. Some pumps plug into an outlet controlled by a wall switch or the furnace service switch. Make sure that switch is on.

☐ 4. Look at the breaker panel. Look only. If a breaker has tripped, leave it and tell the technician.

☐ 5. Follow the tubing. Trace the clear discharge line to where it ends. Note any kinks, sags or tubing pinched behind boxes.

☐ 6. Check where the line ends. If the line drains outside or through a garage, look for ice. Do not chip at it or use heat.

If the reservoir looks full of sludge, leave cleaning to a technician unless your pump's manual describes how to do it. A poorly reassembled pump can leak again. If these checks do not find the cause, a furnace condensate pump not working is a job for a technician.

Clear condensate tubing clipped along a basement wall and ending over a floor drain, with the pump beside the furnace behind it
Following the clear discharge tubing from the pump to the drain is one of the easiest ways to spot a kink, a sag or a blockage.

Winter Trouble Spots: Frozen Lines and Busy Furnaces

A condensing furnace makes the most water on the coldest days, when it runs longest. That is also when a line that ends outdoors or passes through an unheated space is most likely to freeze. The pump pushes against the ice, the tank fills, and the overflow switch shuts the heat off. In the coldest weeks, ice is a common reason for a furnace condensate pump not working.

Our guide to a frozen condensate line explains the signs and lasting fixes, such as rerouting the line indoors.

Mistakes to Avoid

With a furnace condensate pump not working, a few quick fixes do more harm than good:

  • Do not bypass, tape or unplug the overflow switch. It is there to stop water damage.
  • Do not pour bleach, vinegar or drain cleaner into the pump unless the manual allows it. Some chemicals damage seals.
  • Do not keep restarting the furnace. The water has not gone anywhere.
  • Do not open the furnace or touch wiring.

If the basement has flooded above the level of the outlets, the Electrical Safety Authority advises staying out and calling your local electric utility to disconnect power. Ontario also requires carbon monoxide alarms on every storey of a home with a fuel-burning appliance.

How a Technician Fixes a Furnace Condensate Pump Not Working

A repair visit usually follows this order:

StepWhat it covers
Make it safePower off and water cleared from electrical parts
Test the pumpFloat, motor, check valve and overflow switch
Clean the systemReservoir, inlet, furnace trap and drain hoses
Clear the lineBlockages, kinks and ice, rerouting if needed
Repair or replaceA worn or cracked pump is often simply replaced
Confirm the heatA full heating cycle to confirm water drains

Our furnace repair team in Markham handles condensate pumps on every make of high-efficiency furnace. Our service call is $79, and a free Total Home Assessment is available if you are weighing an upgrade.

The best prevention is a yearly tune-up that includes the drain, trap and pump. Members of our maintenance and protection plans get that check plus priority booking in cold weather.

Local Furnace Help Across the GTA

Aire One has helped Ontario homeowners stay warm since 1990. We are TSSA-registered, rated 4.8 stars on Google from 541 reviews and on call 24 hours a day, with financing and a 10-year worry-free warranty. We serve Markham, Richmond Hill and York Region. Learn more about our HVAC company in Markham and our HVAC company in Richmond Hill, or go straight to furnace repair in Markham or furnace repair in Richmond Hill. For a furnace condensate pump not working or a cold house, the Aire One team in Markham can help.

Furnace condensate pump not working?

Our TSSA-registered technicians answer 24/7 across Markham, Richmond Hill and York Region.

310-HEAT (310-4328) · 24/7 service · $79 service call*

Frequently Asked Questions

Is a furnace condensate pump not working an emergency?

It is urgent in winter because the furnace will usually shut off once water backs up. It becomes an emergency if water reaches outlets or cords. In that case, keep everyone away from the water and call a professional right away.

Why is my condensate pump running constantly?

The float may be stuck in the up position, the discharge line may be blocked or frozen, or a failed check valve may be letting water flow back into the tank. A technician can test each part and clear or replace what has failed.

Can I run my furnace if the condensate pump is broken?

Not for long. Without a working pump, water has nowhere to go, so it overflows or the safety switch shuts the furnace off. Never bypass that switch to keep the heat running. Book a repair instead.

Can I clean my condensate pump myself?

Only if the manufacturer's manual describes how, and only after the pump is unplugged and the area is dry. Many homeowners prefer to have it cleaned during a yearly tune-up, when the trap and drain lines are checked too.

Does an air conditioner use the same condensate pump?

Often, yes. The indoor cooling coil usually sits on top of the furnace and often drains into the same pump in summer. That is why sludge from cooling season can cause a pump to fail once the heat comes on.